Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 '3D SPGR' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm '3D SPGR' found in 0 term [] and 0 definition [], (+ 13 Boolean[] results
previous     11 - 13 (of 13)     
Result Pages : [1 2 3]
MRI Resources 
Spine MRI - Distributors - Pacemaker - Examinations - Calculation - Spectroscopy
 
Signa Infinity 1.5Tâ„¢ TwinSpeed with ExciteInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.MRI Resource Directory:
 - Devices -
 
www.gehealthcare.com/usen/mr/s_excite15/index.html From GE Healthcare;
three dedicated MRI systems - a neuro imager, a cardiovascular system, and a whole body scanner - all in one system.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore
Head and body coil standard; all other coils optional; open architecture makes system compatible with a wide selection of coils
Optional 2D/3D brain and prostate
SYNCHRONIZATION
ECG/peripheral, respiratory gating
PULSE SEQUENCES
Standard: SE, IR, 2D/3D GRE and SPGR, Angiography: 2D/3D TOF, 2D/3D Phase Contrast;; 2D/3D FSE, 2D/3D FGRE and FSPGR, SSFP, FLAIR, EPI, optional: 2D/3D Fiesta, FGRET, Spiral, Tensor
IMAGING MODES
Localizer, single slice, multislice, volume, fast, POMP, multi slab, cine
TR
1.2 to 12000 msec in increments of 1 msec
TE
0.4 to 2000 msec in increments of 1 msec
SINGLE/MULTI SLICE
Simultaneous scan and reconstruction;; up to 200 or 400 images per second
1 cm to 48 cm continuous
2D 0.7 mm to 20 mm; 3D 0.1 mm to 5 mm
1280 x 1024
MEASURING MATRIX
128x512 steps 32 phase encode
PIXEL INTENSITY
256 gray levels
60 cm
MAGNET WEIGHT
3863 kg
H*W*D
172 x 208 x 216 cm
POWER REQUIREMENTS
480 or 380/415
COOLING SYSTEM TYPE
Closed-loop water-cooled gradient
Less than 0.03 L/hr liquid He
STRENGTH
Zoom 40 mT/m, whole body 23 mT/m
5-GAUSS FRINGE FIELD
4.0 m x 2.8 m axial x radial
Active
spacer
 
Further Reading:
  News & More:
Twin Gradient Technology - Potential Advantages For Diffusion Weighted MRI(.pdf)
   by www.paulrharvey.co.uk    
MRI Resources 
Calculation - Service and Support - Diffusion Weighted Imaging - Spine MRI - Pediatric and Fetal MRI - Stimulator pool
 
Fast Acquisition with Multiphase EFGRE3DInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(FAME) The FAME MRI technique uses a 3dimensional fast SPGR pulse sequence to acquire high resolution images. With its short scan time, FAME is useful for dynamic liver imaging with multiple phases.
spacer
MRI Resources 
MRI Technician and Technologist Jobs - - Stimulator pool - Implant and Prosthesis - Distributors - Service and Support
 
Fast Spoiled Grass Sequence with IR PreparationInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(IR-FSPGR) This sequence uses an inversion pulse followed by a spoiled low flip angle and short TR gradient echo train to collect all partition data. The 3D-IR-FSPGR uses centric ordering of Gz. The selected TI is also the effective TI. The centric reordering strategy can lead to image blurring if a steady state is not achieved quickly with low flip angles (less than 20°).
spacer
MRI Resources 
Image Quality - Supplies - Spectroscopy - Functional MRI - Coils - Stent
 
previous      11 - 13 (of 13)     
Result Pages : [1 2 3]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 28 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]